Fiber Optic Patch Cord
Applications
Date communication;
Telephone communication Network;
Test equipment;
LAN;
Fiber optic CATV;
Access Network.
1. FC OR SC Fiber Optic Connector
Features
UPC, APC polishing
High return loss, Low insertion loss
High reliability and stability
Specifications
|
Test Item
|
Test Condition
|
Value(dB)
|
UPC
|
APC
|
Optical Performance
|
Insertion Loss
|
1310nm LED light source
|
<0.3
|
<0.3
|
Return Loss
|
1310nm LD light source
|
>50
|
>60
|
Environmental Performance
(Max. Insertion Loss change)
|
High temperature
|
+85oC,168 hours
|
<0.2
|
Temperature Cycle
|
-40-+75oC,21 Cycles 168 hours
|
<0.2
|
Humidity Aging
|
+75oC,95%R.H,168 hours
|
<0.2
|
Humidity/Condensation Cycling
|
-10-+65oC,90%~100%RH, 14 cycles 168 hours
|
<0.2
|
Mechanical Performance
( Max. Insertion Loss change)
|
Vibration
|
10-55Hz,1.5mm(p-p)
|
<0.2
|
Flex
|
0.9kgf,-90o~+90o repeat for 100 cycles
|
<0.2
|
Torsion
|
1.35kgf,±900o,10times
|
<0.2
|
Withstand tensile
|
90N,10min
|
<0.2
|
Drop
|
H=1.5M,Total of 8 drops
|
<0.2
|
Exchangeability
|
Randomly
|
<0.2
|
Durability
|
500 times
|
<0.2
|
2. ST Fiber Optic Connector
Features:
PC, UPC polishing
High return loss, Low insertion loss
High reliability and stability
Specifications
|
Test Item
|
Test Condition
|
Value(dB)
|
UPC
|
Optical Performance
|
Insertion Loss
|
1310nm LED light source
|
<0.3
|
Return Loss
|
1310nm LD light source
|
>50
|
Environmental Performance
(Max.Insertion Loss change)
|
High temperature
|
+85oC,168 hours
|
<0.2
|
Temperature Cycle
|
-40-+75oC,21 Cycles 168 hours
|
<0.2
|
Humidity Aging
|
+75oC,95%R.H,168 hours
|
<0.2
|
Humidity/Condensation Cycling
|
-10-+65oC,90%~100%RH,14 cycles 168 hours
|
<0.2
|
Mechanical Performance
( Max.Insertion Loss change)
|
Vibration
|
10-55Hz,1.5mm(p-p)
|
<0.2
|
Flex
|
0.9kgf,-90o~+90o repeat for 100 cycles
|
<0.2
|
Torsion
|
1.35kgf, ±900o,10times
|
<0.2
|
Withstand tensile
|
90N,10min
|
<0.2
|
Drop
|
H=1.5M,Total of 8 drops
|
<0.2
|
Exchangeability
|
Randomly
|
<0.2
|
Durability
|
500 times
|
<0.2
|
3.LC OR MU Fiber Optic Connector
Features
UPC, APC polishing;
Push-pull structure;
High return loss, Low insertion loss;
High reliability and stability Compact size .
Specifications
|
Test Item
|
Test Condition
|
Value(dB)
|
UPC
|
APC
|
Optical Performance
|
Insertion Loss
|
1310nm LED light source
|
<0.3
|
<0.3
|
Return Loss
|
1310nm LD light source
|
>50
|
>55
|
Environmental Performance
(Max.Insertion Loss change)
|
High temperature
|
+85oC,168 hours
|
<0.2
|
Temperature Cycle
|
-40-+75oC, 21 Cycles 168 hours
|
<0.2
|
Humidity Aging
|
+75oC, 95%R.H,168 hours
|
<0.2
|
Humidity/Condensation Cycling
|
-10-+65oC, 90%~100%RH, 14 cycles 168 hours
|
<0.2
|
Mechanical Performance
(Max.Insertion Loss change)
|
Vibration
|
10-55Hz, 1.5mm(p-p)
|
<0.2
|
Flex
|
0.6kgf,-90o~+90o repeat for 100 cycles
|
<0.2
|
Torsion
|
1.35kgf, ±900o,10times
|
<0.2
|
Withstand tensile
|
70N,10min
|
<0.2
|
Drop
|
H=1.5M,Total of 8 drops
|
<0.2
|
Exchangeability
|
Randomly
|
<0.2
|
Durability
|
500 times
|
<0.2
|